Siemens 6GT2001-0AA00 MOBY SLG 41 RFID Read Write Device

Original price was: $3,900.00.Current price is: $3,150.00.

Parameter Details
Model 6GT2001-0AA00
Brand Siemens
Product Family SIMATIC NET / MOBY I RFID System
Core Function Reads and writes identification data from MOBY I data memory tags (MDS) for industrial tracking applications.
Product Type RFID Read/Write Device
Device Type SLG 41
Operating Voltage 24 VDC
Protection Rating IP65
Maximum Read/Write Distance Up to 25 mm depending on MDS type
Communication Rate 19.2 kbaud
Brand: Model/SKU: 6GT2001-0AA00

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WhatsApp QR Code WhatsApp
WeChat QR Code WeChat

Description

Product Introduction & Engineering Value

RFID systems in production environments are usually installed because manual identification has already reached its limit. The Siemens 6GT2001-0AA00 MOBY I SLG 41 provides reliable contactless identification by reading and writing data stored in MOBY I identification tags.

This unit was widely used in Siemens automation environments for material tracking, assembly identification, and production logistics. Although it is a legacy MOBY I component, many plants continue operating it because the surrounding automation equipment remains functional and replacement requires system-level planning.

 

Technical Specifications

Specification Details
Manufacturer Siemens
Article Number 6GT2001-0AA00
RFID System MOBY I
Device Model SLG 41
Product Type RFID Write/Read Device
Supply Voltage 24 VDC
Current Consumption Approx. 0.1 A
Communication Speed 19.2 kbaud
Operating Temperature -25 °C to +70 °C
Protection Class IP65
Dimensions 120 × 40 × 40 mm
Weight Approximately 210 g
Maximum Operating Distance 25 mm (depending on MDS)

 

Field Application & The “Trench” Experience

A European automotive supplier running an older Siemens S5-based assembly line began seeing intermittent identification failures at several workstation points. Operators reported that carriers occasionally stopped because the system could not confirm the correct product information.

The engineering team first replaced several identification tags, assuming the problem was caused by damaged MDS units. The failures continued. During deeper troubleshooting, technicians found that one aging SLG 41 read/write head had unstable communication behavior caused by internal degradation.

Installing a tested Siemens 6GT2001-0AA00 restored reliable tag communication without modifying the PLC program or replacing the entire RFID system.

Common application scenarios include:

  • Automotive assembly carrier identification
  • Machine tool pallet tracking systems
  • Production line workpiece routing using MOBY I tags
  • Material handling stations requiring automatic identification
6GT2001-0AA00

6GT2001-0AA00

6GT2001-0AA00

6GT2001-0AA00

Transparency SOP: QA & Testing

For legacy RFID components, functional testing matters more than appearance.

Verification procedure:

1. Product Identification

  • Confirm Siemens label.
  • Verify exact article number: 6GT2001-0AA00.
  • Check SLG 41 marking.

2. Physical Inspection

  • Inspect housing condition.
  • Check connector integrity.
  • Verify IP65 sealing condition.
  • Look for moisture or impact damage.

3. RFID Functional Test

  • Apply 24 VDC power.
  • Verify communication with compatible MOBY I interface equipment.
  • Perform read/write test with supported MDS tags.
  • Confirm stable operating distance.

4. Documentation

  • Record serial number.
  • Document test results.
  • Classify inventory condition:
    • New Surplus
    • Refurbished
    • Tested Used

 

The Veteran’s Tech Trap Guide

⚠️ Trap #1: Assuming Any Siemens RFID Head Is a Replacement

The MOBY family contains multiple RFID generations.

PRO TIP: Verify:

  • RFID family compatibility
  • MDS tag type
  • Communication module type
  • PLC interface architecture

A newer SIMATIC RF component is not automatically a direct replacement for MOBY I equipment.

⚠️ Trap #2: Ignoring Read Distance Requirements

The SLG 41 has a maximum operating distance of approximately 25 mm depending on the MDS.

Incorrect mechanical mounting can cause:

  • Missed reads
  • Intermittent identification
  • Reduced production reliability

⚠️ Trap #3: Forgetting Legacy Lifecycle Status

The 6GT2001-0AA00 has reached the end of its product lifecycle and has been discontinued by Siemens.

For plants still operating MOBY I systems:

  • Maintain tested spare readers
  • Document installed RFID configurations
  • Evaluate migration timing before emergency replacement is required

 

Dynamic FAQ

Q1. What is the Siemens 6GT2001-0AA00 used for?

The Siemens 6GT2001-0AA00 is a MOBY I SLG 41 RFID read/write device used for contactless identification and data exchange with compatible MOBY I data memory tags.

Q2. What is the maximum read/write distance of 6GT2001-0AA00?

The maximum operating distance is approximately 25 mm, depending on the connected MDS identification tag.

Q3. Is the 6GT2001-0AA00 still a current Siemens product?

No. Siemens documentation indicates that this MOBY I component has reached the end of its lifecycle and has been discontinued.

Q4. Can the 6GT2001-0AA00 be replaced by a newer SIMATIC RF reader?

Not directly in every installation. Replacement requires checking:

  • Existing PLC interface
  • Communication module
  • Tag technology
  • Mechanical mounting
  • Software compatibility

Q5. What should buyers verify when purchasing New Surplus 6GT2001-0AA00?

Recommended checks:

  • Original Siemens marking
  • SLG 41 model confirmation
  • Housing and connector condition
  • RFID read/write test results
  • Storage history
  • Warranty terms

Q6. Is refurbished 6GT2001-0AA00 suitable for plant spare inventory?

Yes, if the unit has passed RFID communication testing and physical inspection. For legacy production systems, tested refurbished RFID heads are often maintained as emergency replacement inventory.