Honeywell 51199929-100 TDC 3000 Power Supply

Original price was: $8,955.00.Current price is: $3,190.00.

Parameter Specification
Model 51199929-100
Alternate Model SPS5710
Brand Honeywell
Product Type Power supply module
System Association Honeywell TDC 3000 / Series C power system
Input 100–240 VAC, 47–63 Hz
Input Current 10 A
Output 24–26 VDC
Output Current 20 A
Related OEM/TDI P/N TDI 140519

Honeywell 51199929-100 is identified as the SPS5710 power supply, with published specifications of 100–240 VAC input, 47–63 Hz, 10 A, and 24–26 VDC output at 20 A. DCS Center also identifies TDI P/N 140519 as an alternate part reference.

Brand: Model/SKU: 51199929-100

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WhatsApp QR Code WhatsApp
WeChat QR Code WeChat

Description

Product Introduction & Engineering Value

The Honeywell 51199929-100 SPS5710 is a high-current DC power supply used in Honeywell control-system power architectures. Its documented electrical specification is substantially different from a small controller power module: the unit accepts 100–240 VAC and provides a 24–26 VDC, 20 A output. It is also identified for Class I, Division 2, Zone 2 applications in industrial inventory documentation.

For replacement work, verify the installed system, power architecture, connector arrangement, and nameplate revision before installation. Some online listings incorrectly describe this part as a ControlNet communication module or machinery-protection device; those descriptions conflict with multiple independent sources identifying 51199929-100 as SPS5710 power supply hardware.

 

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Part Number 51199929-100
Model SPS5710
Alternate Part Number 51199929100
TDI Part Number 140519
Product Type AC/DC power supply
Input Voltage 100–240 VAC
Input Frequency 47–63 Hz
Input Current 10 A
Output Voltage 24–26 VDC
Output Current 20 A
Power Architecture 20 A redundant power-system application
Classification Class I, Division 2 / Zone 2 listed by suppliers
Approx. Weight 4.74 lb / 2.15 kg
Manufacturer Status Discontinued according to Radwell

The electrical ratings above are supported by multiple current industrial-parts references. DCS Center lists a 100–240 VAC, 47–63 Hz, 10 A input and 24–26 VDC, 20 A output; IMS Supply reports the same ratings and identifies the model as SPS5710.

DCS Center lists the country of origin as China and describes the unit as made for Honeywell by Transistor Devices Inc. (TDI). Its alternate TDI reference is 140519.

 

Field Application & The “Trench” Experience

A realistic maintenance problem with the 51199929-100 starts with a control system that intermittently loses its DC supply while the incoming AC remains stable. The first instinct may be to troubleshoot the controller or I/O modules. An experienced technician checks the power architecture first: incoming voltage, DC output, load current, connections, and any redundant supply arrangement.

Once the SPS5710 is identified as the suspect unit, the technician records the complete 51199929-100 part number and revision, checks the mating connections, and confirms that the replacement has the same power-system role. After installation, the DC output is verified before the downstream control modules are returned to normal operation.

This is particularly important with a 20 A power supply. A replacement should be evaluated as part of the complete power-distribution architecture, not simply as a generic 24 VDC supply.

Specific Application Scenarios

  • Honeywell TDC 3000 / Series C power-system maintenance
  • Redundant DCS power architecture, where a failed supply must be replaced without disturbing the remaining supply
  • Legacy process-control cabinet maintenance requiring a 20 A regulated DC source
  • Classified industrial environments, subject to verification of the actual system installation and applicable certification requirements
51199929-100

51199929-100

51199929-100

51199929-100

Transparency SOP: QA & Testing

For new-surplus or refurbished Honeywell 51199929-100, a meaningful QA process should include:

1. Identity verification
Check the Honeywell part number, SPS5710 designation, revision, serial information, and any TDI 140519 markings.

2. Physical inspection
Inspect the enclosure, AC input terminals, DC output connections, cooling path, PCB assembly, mounting hardware, and visible components.

3. Input-stage test
Apply an appropriate AC input within the documented range and verify stable startup behavior.

4. DC output test
Measure the output under suitable load conditions. Confirm that the output remains within the applicable 24–26 VDC specification.

5. Load test
Where the test facility permits, perform controlled load testing toward the rated 20 A output rather than relying only on a no-load voltage measurement.

6. Redundancy/system test
If the unit is being used in a redundant power architecture, test the applicable failover behavior using the correct system procedure.

7. Final QA record
Record the unit’s exact condition, revision, test scope, measured values, and supplied accessories.

“New surplus” should mean unused inventory; it should not automatically be interpreted as current-production Honeywell factory stock. Radwell separately distinguishes never-used original packaging, never-used repackaged, and refurbished conditions for this part.

 

The Veteran’s Tech Trap Guide

⚠️ Trap #1 — Do not treat every 24 VDC supply as a substitute.
The SPS5710 is rated for 20 A output. A generic 24 VDC supply with insufficient current capacity or the wrong power-system interface is not an equivalent replacement.

⚠️ Trap #2 — Verify the exact system architecture.
Some supplier listings associate the 51199929-100 with TDC 3000, while others also reference Series C power systems. Confirm the installed cabinet and power-system documentation rather than relying on a broad product-category label.

PRO TIP: Record both the Honeywell 51199929-100 and markings from the original unit. If a TDI label is present, record 140519 as well. Multiple identifiers make legacy-spare sourcing much easier.

⚠️ Trap #3 — Be careful with incorrect web descriptions.
One current listing describes 51199929-100 as a ControlNet interface, while several other sources independently identify it as the SPS5710 power supply. The latter identification is supported by the explicit electrical ratings and alternate model numbers.

⚠️ Trap #4 — Do not skip loaded testing.
A power supply can show a normal DC voltage with almost no load and still fail when the system demands substantial current. For a 20 A-rated unit, controlled load testing provides considerably more useful evidence than a simple open-circuit voltage check.

 

FAQ

1. What is Honeywell 51199929-100?

Honeywell 51199929-100 is the SPS5710 power supply, used in Honeywell industrial control power architectures. It is documented with a 100–240 VAC input and 24–26 VDC, 20 A output.

2. What is the output rating?

The published specification is 24–26 VDC at 20 A. The input is listed as 100–240 VAC, 47–63 Hz, 10 A.

3. What is the SPS5710?

is the model designation associated with Honeywell part 51199929-100. The unit is also associated with TDI part number 140519 in industrial spare-parts documentation.

4. Is 51199929-100 discontinued?

Radwell currently identifies 51199929-100 as discontinued by the manufacturer. This makes verified surplus, unused, and refurbished inventory relevant to legacy-system maintenance.

5. Is 51199929-100 the same as a ControlNet communication module?

No. The stronger available evidence identifies it as an SPS5710 power supply, not a ControlNet communication module. The conflicting ControlNet description found on one supplier page should not be used as the technical basis for procurement.

6. Can it be supplied as new surplus?

Yes, the part appears in current industrial spare-parts inventories with unused and refurbished condition categories. The actual condition must be confirmed for the specific unit being supplied.

7. What warranty should buyers expect?

Warranty depends on the supplier and product condition. For example, Radwell states a two-year warranty for its listed units, while other suppliers advertise one-year coverage. These are supplier warranties and should not be represented as an original Honeywell factory warranty.