Schneider AS-P890-000R Modicon Remote I/O Module

Original price was: $1,850.00.Current price is: $1,135.00.

Parameter Details
Model requested AS-P890-000R
Manufacturer Schneider Electric
Product family Modicon 984 Series
Product type Remote I/O interface; confirm exact suffix
Primary function Interfaces a compatible PLC control system with remote I/O equipment
Network architecture Single-cable Remote I/O on the documented AS-P890-000 variant
Lifecycle context Legacy automation hardware
Procurement priority Verify suffix, hardware revision, condition, and system compatibility

The AS-P890-000 reference is documented by industrial parts distributors as a Modicon 984 Series single-cable RIO interface. Do not assume that every specification for AS-P890-000 applies unchanged to AS-P890-000R.

Brand: Model/SKU: AS-P890-000R

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WhatsApp QR Code WhatsApp
WeChat QR Code WeChat

Description

Product Introduction & Engineering Value

Legacy PLC systems often remain in service long after their original hardware becomes difficult to source. The Schneider Electric AS-P890-000R is a model to investigate when maintaining a Modicon 984 installation that relies on remote I/O communications. The closely related AS-P890-000 is listed as a single-cable RIO interface, making exact part-number verification essential before substitution.

For maintenance teams, the main objective is restoring the existing control architecture without introducing an unverified interface or wiring change. Confirm the installed controller, remote I/O adapter, cable arrangement, and module revision before removing the existing unit.

 

Technical Specifications

The following parameters are documented for the standard AS-P890-000 variant. Confirm the AS-P890-000R nameplate before using these values for procurement or engineering approval.

Parameter Documented specification
Product family Modicon 984
Interface type Remote I/O interface
Supported I/O family Modicon 800 Series I/O
Communication protocol S908 (HDLC)
Remote I/O connection Single coaxial cable connector
Supported topology Single- or dual-cable arrangements; not redundant-cable topology
Integrated power supply Yes
Input power options 115/230 VAC or 24 VDC, as documented for the family
DC output rails +5 VDC, +4.3 VDC, and −5 VDC
Maximum documented output ratings +5 VDC: 3 A; +4.3 VDC: 3 A; −5 VDC: 0.25 A
Operating temperature 0 to 60°C (32 to 140°F)
Relative humidity 0–95%, noncondensing
Installation position Slot 1 of the primary remote I/O housing
Weight Approximately 5 lb (2.25 kg)

Reference: Modicon 984 PLC and 800-Series I/O technical documentation. Power-output ratings must be evaluated against the specified combined load limits; individual rail ratings are not permission to draw all maximum currents simultaneously.

 

Field Application and Maintenance Scenario

Illustrative engineering scenario — not a documented customer installation.

A manufacturing facility experiences a loss of communication with a remote I/O drop serving conveyor interlocks and motor permissive signals. The maintenance team suspects the RIO interface because the remote rack no longer exchanges data with the Modicon 984 controller.

Before replacing the interface, the engineer checks the coaxial cable connection, verifies the remote drop’s power supply, and reviews controller diagnostics. A replacement AS-P890-000R is considered only after its identity and compatibility with the installed hardware are confirmed.

Following installation, the team verifies communication recovery, checks representative input and output states, and tests affected interlocks under the site’s approved commissioning procedure.

Application scenarios

  • Conveyor interlock control: Remote discrete I/O used for permissive signals, equipment status, and interlocking logic.
  • Legacy packaging machinery: Distributed 800 Series I/O in an established Modicon 984 control architecture.
  • Process utility skids: Remote signal acquisition and control for auxiliary equipment where an existing S908 RIO network remains in service.

These scenarios describe potential uses of the documented product family, not confirmed installations of the exact AS-P890-000R variant. The interface is intended for compatible 800 Series remote I/O drops using the S908 protocol.

AS-P890-000R

AS-P890-000R

AS-P890-000R

AS-P890-000R

Quality Assurance and Testing Procedure

For legacy control hardware, a credible quality process should document what was actually inspected and tested. A seller’s condition label alone is not sufficient evidence of operational performance.

A recommended inspection and release procedure is:

  1. Verify identity. Record the complete catalog number, manufacturer markings, hardware revision, and any identifying labels.
  2. Inspect physical condition. Check connectors, circuit boards, terminals, mounting features, and signs of corrosion, overheating, or unauthorized repair.
  3. Check power characteristics. Where supported by the test setup, verify the applicable input and output rails against the technical documentation.
  4. Test communication. Use a compatible Modicon 984 and 800 Series I/O configuration to confirm RIO communication and basic interface operation.
  5. Record results. Document the test configuration, observed faults, repair history if known, and final acceptance status.

Condition terminology matters:

  • New surplus: Previously purchased or stocked inventory that is represented as unused. This designation does not, by itself, establish OEM authorization or prove that the unit has been tested.
  • Refurbished: Previously used hardware that has undergone some level of inspection, repair, or restoration. Ask for the actual work performed and test results.
  • Tested working: A functional claim that should be supported by a defined test scope and recorded results.

Do not advertise a unit as fully load-tested, factory-certified, or genuine OEM stock unless the available documentation supports that claim.

 

Replacement Pitfalls: What Experienced Engineers Check First

Pitfall 1: Treating AS–000R as an exact catalog match

The available technical documentation identifies AS–000, not the complete AS–000R designation. Request a clear photograph of the nameplate and compare the full catalog number before approving the purchase.

Pitfall 2: Confusing dual-cable operation with redundant-cable support

The documented has one RIO cable connector and supports single- and dual-cable arrangements, but not redundant-cable topology. If the plant requires redundant RIO cabling, do not assume this module is suitable. Verify the controller and interface configuration against the system documentation.

Pitfall 3: Ignoring remote-rack power requirements

The includes an integrated power supply. Before commissioning, calculate the actual current demand of the installed I/O modules and check the applicable combined rail limits. Never assume that a replacement is suitable simply because it fits the rack.

PRO TIP: Record the original wiring, rack slot, power configuration, and controller diagnostics before removing a failed interface. Follow the plant’s isolation and electrical safety procedures, and validate the restored I/O states before returning the equipment to service.

 

Frequently Asked Questions

Q1. What does the Schneider Electric AS- do?

The requested part number is associated with the Modicon 984 interface family. The documented AS–000 provides remote I/O communications for compatible Modicon 800 Series I/O using the S908 protocol and includes an integrated power supply. The exact AS- suffix should be verified before purchase.

Q2. Can AS–000 be used as a replacement for AS-?

Not without confirming the catalog designation and hardware compatibility. Compare the complete part number, nameplate, connector arrangement, and installed system configuration. Obtain written confirmation from the supplier if the offered part number differs from the requested number.

Q3. Does this module support ASCII communications?

The standard interface does not provide the ASCII communications functionality documented for the P892. The P892 includes two half-duplex ASCII ports in addition to its RIO and power-supply functions. Do not substitute a for a P892 where the application depends on those ports.

Q4. What should I provide when requesting a quotation?

Provide the full part number, a nameplate photograph if available, required quantity, acceptable condition (new surplus or refurbished), destination country, and any required warranty period. If the module is intended to replace an installed unit, include the existing model number and relevant rack configuration.

Q5. How can I verify that new-surplus stock is authentic?

Request photographs of the actual unit, readable manufacturer markings, traceability records where available, and a written condition declaration. New-surplus status does not automatically prove that the part came directly from Schneider Electric or an authorized distributor.

Q6. What warranty applies to AS-?

Warranty coverage depends on the seller and the specific unit offered. Confirm the warranty duration, coverage for functional failure, return authorization procedure, and remedy for a defective unit in writing before placing the order. Do not assume that a warranty offered for AS–000 automatically applies to AS-.