IC676PBO082 GE Profibus Digital Output Module 24 VDC

Original price was: $3,110.00.Current price is: $2,175.00.

  • 3. Product Introduction

    The GE IC676PBO082 is an 8-point digital output block used in GE automation systems for field device actuation. It is built for PROFIBUS DP-based distributed I/O applications and is commonly used to switch relays, solenoids, lamps, and other 24 VDC loads in industrial panels.amikonplc.made-in-china+2

    Its strength is straightforward integration. In legacy distributed control or machine control cabinets, this module lets you keep the existing network and field wiring model intact instead of redesigning the output layer from scratch. It is a practical spare for installed-base systems that still need clean digital actuation and bus-side compatibility.ddpartssolution+2

    4. Key Technical Specifications

    Parameter Value
    Model IC676PBO082
    Manufacturer GE Fanuc / GE
    Product Family PACSystems / Field Control
    Product Type Digital Output Block
    Output Channels 8 points
    Output Voltage 24 VDC
    Output Type Positive logic
    Communication PROFIBUS DP
    Connector Type M12
    Baud Rate Up to 12 Mbaud, autobaud
    Application Digital actuators, relays, solenoids
    Mounting Field-mounted distributed I/O

    5. Application Scenarios & The “Trench” Experience

    A common trench problem is a remote output block that fails while the rest of the line is still healthy. The operator sees the PLC running, but one actuator chain is dead because the field output module is not talking or not switching. That’s the kind of failure that turns a small part number into a production emergency.amikonplc.made-in-china+2

    • Manufacturing – Machine actuation – Used for 24 VDC on/off control of solenoids, relays, and pilot devices.ddpartssolution+1

    • Process automation – Distributed output control – Required when a remote Profibus station must remain in service.cxdcs+1

    • Packaging lines – Interlock outputs – Needed for deterministic switching of field devices in a compact cabinet.nordwel+1

    • Retrofit support – Legacy network preservation – Chosen when the existing bus and field wiring must stay intact.ddpartssolution+1

    Field case: a plant lost one Profibus output block feeding several machine interlocks. The PLC itself never faulted, which made the failure annoying and expensive to diagnose. A direct replacement of the IC676PBO082 restored the remote outputs and avoided a larger control redesign, which is exactly why plants keep these modules in spare stock.amikonplc.made-in-china+1

    6. Transparency SOP: Quality Assurance & Testing

    We don’t just ship boxes; we test them on actual GE racks.

    • Inbound Inspection: Verify part number, suffix, connector condition, labeling, and counterfeit indicators.

    • Live Rig Testing: Power the unit on a known-good test setup and confirm PROFIBUS communication.

    • Electrical Parameter Checks: Verify output switching behavior, load response, and supply integrity.

    • Firmware Verification: Record the exact hardware revision and communication behavior during test.

    • Final QC & Anti-static Packaging: Clean, function-test, and pack with ESD protection before release.

    7. The Veteran’s Tech Trap Guide

    • ⚠️ Don’t confuse the network. This is a PROFIBUS field output block. It is not a generic PLC output card.

    • ❗ Check the voltage class. It is a 24 VDC output device. Put AC field wiring on it and you will buy a second one.

    • ⚠️ M12 and termination details matter. One bad connector or shield mistake can make the block look dead.

    • ❗ Match the logic type. Positive logic output behavior matters when the field device expects sourcing, not sinking.

    8. Frequently Asked Questions (FAQ for Conversion)

    Q: Is IC676PBO082 hot-swappable?
    A: No. Do not treat it like a casual live-swap part. Isolate the station before replacement.

    Q: What protocol does it use?
    A: PROFIBUS DP.amikonplc.made-in-china+1

    Q: How many outputs does it have?
    A: Eight 24 VDC output points.ddpartssolution+1

    Q: What kinds of loads can it drive?
    A: Relays, solenoids, pilot lights, and other 24 VDC digital loads.cxdcs+1

    Q: Is this cheaper than OEM direct supply?
    A: Usually yes, because available stock often comes from surplus or recovered installed base, not factory production.

    Q: Is it fake or refurbished?
    A: The market is mixed. The safe move is to demand photos, test evidence, and revision details before you buy.

    Q: Does it come with a warranty?
    A: Many surplus vendors offer 12 months, but the exact warranty depends on the seller.

    Model: IC676PBO082

  • Brand: GE Fanuc / GE
  • Series: PACSystems / Field Control
  • Core Function: Drives 24 VDC digital field loads over a fieldbus interface.
  • Product Type: Digital Output Module
  • Key Specs: 8 output points | 24 VDC | PROFIBUS DP / M12 connection
  • Condition: ⚠️ Discontinued – Limited Stock Available
Brand: Model/SKU: IC676PBO082

Get a Quote / Inquiry

Phone/WhatsApp/Wechat:
WhatsApp QR Code WhatsApp
WeChat QR Code WeChat

Description

Product Introduction

The GE IC676PBO082 is an 8-point digital output block used in GE automation systems for field device actuation. It is built for PROFIBUS DP-based distributed I/O applications and is commonly used to switch relays, solenoids, lamps, and other 24 VDC loads in industrial panels.

Its strength is straightforward integration. In legacy distributed control or machine control cabinets, this module lets you keep the existing network and field wiring model intact instead of redesigning the output layer from scratch. It is a practical spare for installed-base systems that still need clean digital actuation and bus-side compatibility.

 

Key Technical Specifications

Parameter Value
Model IC676PBO082
Manufacturer GE Fanuc / GE
Product Family PACSystems / Field Control
Product Type Digital Output Block
Output Channels 8 points
Output Voltage 24 VDC
Output Type Positive logic
Communication PROFIBUS DP
Connector Type M12
Baud Rate Up to 12 Mbaud, autobaud
Application Digital actuators, relays, solenoids
Mounting Field-mounted distributed I/O

 

Application Scenarios & The “Trench” Experience

A common trench problem is a remote output block that fails while the rest of the line is still healthy. The operator sees the PLC running, but one actuator chain is dead because the field output module is not talking or not switching. That’s the kind of failure that turns a small part number into a production emergency.

  • Manufacturing – Machine actuation – Used for 24 VDC on/off control of solenoids, relays, and pilot devices.
  • Process automation – Distributed output control – Required when a remote Profibus station must remain in service.
  • Packaging lines – Interlock outputs – Needed for deterministic switching of field devices in a compact cabinet.
  • Retrofit support – Legacy network preservation – Chosen when the existing bus and field wiring must stay intact.

Field case: a plant lost one Profibus output block feeding several machine interlocks. The PLC itself never faulted, which made the failure annoying and expensive to diagnose. A direct replacement of the IC676PBO082 restored the remote outputs and avoided a larger control redesign, which is exactly why plants keep these modules in spare stock.

IC676PBO082
IC676PBO082
IC676PBO082
IC676PBO082

 

Transparency SOP: Quality Assurance & Testing

We don’t just ship boxes; we test them on actual GE racks.

  • Inbound Inspection: Verify part number, suffix, connector condition, labeling, and counterfeit indicators.
  • Live Rig Testing: Power the unit on a known-good test setup and confirm PROFIBUS communication.
  • Electrical Parameter Checks: Verify output switching behavior, load response, and supply integrity.
  • Firmware Verification: Record the exact hardware revision and communication behavior during test.
  • Final QC & Anti-static Packaging: Clean, function-test, and pack with ESD protection before release.

 

The Veteran’s Tech Trap Guide

  • ⚠️ Don’t confuse the network. This is a PROFIBUS field output block. It is not a generic PLC output card.
  • ❗ Check the voltage class. It is a 24 VDC output device. Put AC field wiring on it and you will buy a second one.
  • ⚠️ M12 and termination details matter. One bad connector or shield mistake can make the block look dead.
  • ❗ Match the logic type. Positive logic output behavior matters when the field device expects sourcing, not sinking.

 

Frequently Asked Questions (FAQ for Conversion)

Q: Is IC676PBO082 hot-swappable?
A: No. Do not treat it like a casual live-swap part. Isolate the station before replacement.

Q: What protocol does it use?
A: PROFIBUS DP.

Q: How many outputs does it have?
A: Eight 24 VDC output points.

Q: What kinds of loads can it drive?
A: Relays, solenoids, pilot lights, and other 24 VDC digital loads.

Q: Is this cheaper than OEM direct supply?
A: Usually yes, because available stock often comes from surplus or recovered installed base, not factory production.

Q: Is it fake or refurbished?
A: The market is mixed. The safe move is to demand photos, test evidence, and revision details before you buy.

Q: Does it come with a warranty?
A: Many surplus vendors offer 12 months, but the exact warranty depends on the seller.